KIP - STATION INSTRUMENTATION

2. Global Seismograph Network - GSN:  [ IU ]

DATES OF OPERATION:  	29 Jul 1995 to Present.

SEISMOMETER TYPE AND ADC:
Streckeisen STS-2 very broadband seismometer and Kinemetrics FBA-23 low-gain 
accelerometer.  ADC is Quanterra QX80.

DIGITAL FORMAT:
24 bit integer data words for all broadband, long period, very long period and
ultra long period channels.  Range: +8,388,607 to -8,388,608 counts
16 bit integer data words for mass position and all environmental channels.
Range:  +32767 to -32768

EVENT DETECTOR ALGORITHIM:  
The Murdock event detector (Murdock, 1991) is used for the very short period data.

Click on any of the following items for further information.
The Noise Study was done using 1992 data, consequently, it is only an estimation for this generation of station instrumentation.